Item
|
Value
|
Operating Speed
|
0.1mm~1m/s(Related with actuator forms)
|
Operating Frequency
|
Mechanical 60 cycles/min;Electrical 30 cycles/min
|
Insulation Resistance
|
100 MΩ (500VDC)
|
Contact resistance
|
<=30mΩ(Initial value)
|
Test Voltage
|
Between terminals of the same polarirty
|
AC1000V,50/60Hz,1min
|
Between current-carrying metal
And ground(case),and between
Each terminal and non-carrying
metal parts
|
AC2000V,50/60Hz,1min
|
Vibration resistance
|
10-55Hz,1.5mm Double amplitude
|
Shork Resistance
|
Destruction : OF>0.5N:1000m/s ²(approx.100G)max
OF<=0.5N:500m/s ²(approx.50G)max
Malfunction: OF>0.5N:300m/s ²(approx.30G)max
OF<=0.5N:200m/s ²(approx.20G)max
|
Life Expectancy
|
Mechnical>=5000000 cycles
Electrical>=50000 cycles
|
Degree of protection
|
IEC IP40
|
Degree of protection against electric shock
|
Class I
|
PTI(Tracking Resistance)
|
175
|
Ambient air temperature
|
125℃ 60%RH below(No ice and dew)
|
Ambient air humidity
|
85% Rhbelow(about +5~+35℃)
|
Weight
|